Specification

Place of Origin:
China
Brand Name:
Fluke
Model Number:
T6-1000
Display Type:
Digital Only
Measuring Current Range:
AC 200A
Measuring Voltage Range:
1000V
Measuring Resistance Range:
2000 Ω 20.00kΩ 100.0kΩ
Operating Temperature:
-10°C-+50°C
Dimensions:
61.1mm*259.3mm*43.8mm
Weight:
0.35kg
Product name:
Clamp Multimeter
Jaw Opening:
17.8mm
Frequency:
45Hz-66Hz
Safety Level:
1000V CAT III 600V CAT IV
Color:
Yellow
Calibration:
1-year calibration cycle
Packing:
Storage Case

৳ 87,500.00 ৳ 98,000.00

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-rms
No 1000 V 1 V ± (3 % + 3 counts) 45 Hz – 66 Hz[2][3]
FieldSense
ac current true-rms
No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz – 66 Hz
FieldSense
frequency (Hz)
No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
Volts ac true-rms Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz – 66 Hz
Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
Safety 1000 V CAT III
600 V CAT IV
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

 

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
Storage -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating 2,000 m (6,562 feet)
Storage 10,000 m (32,808 feet)
Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
0.1 x (specified accuracy) / °C for <18°C or >28 °C
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable