CHINT NXBLE-32 3P+N 6A 10A 16A 20A 32A Earth Leakage Circuit Breaker ELCB
dz47le earth leakage mini circuit breaker Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In ≤ 30 mA: additional protection in the case of direct
contact In ≤300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
dz47le earth leakage mini circuit breaker SPEC:
| Standard | IEC/EN 60898-1 | ||
|
Electrical features |
Type (wave form of the earth leakage sensed) | AC | |
| Thermo-magnetic release characteristic | C, D | ||
| Rated current In | A | 6, 10, 16, 20 , 32 | |
| Rated voltage Ue | V | 230/400 | |
| Rated sensitivity In | A | 0.03, 0.1, 0.3 | |
| Rated residual making and breaking capacity Im |
A |
500 |
|
| Rated short-circuit capacity lcn | A | 4,500/6,000 | |
| Break time under In | s | ≤0.1 | |
| Rated frequency | Hz | 50/60 | |
| Rated impulse withstand voltage (1.2/50)Uimp |
V |
4,000 |
|
| Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | |
| Insulation voltage Ui | 500 | ||
| Pollution degree | 2 | ||
|
Mechanical features |
Electrical life | 2,000 | |
| Mechanical life | 2,000 | ||
| Contact position indicator | Yes | ||
| Protection degree | IP20 | ||
| Ambient temperature
(with daily average≤35°C) |
°C |
-5…+40 (Special application please refer to P72 for temperature compensation correction) | |
| Storage temperature | °C | -25…+70 | |
|
Installation |
Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
|
Terminal size top/bottom for cable |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Terminal size top/bottom for busbar |
mm2 | 25 | |
| AWG | 18-3 | ||
|
Tightening torque |
N*m | 2 | |
| In-Ibs. | 18 | ||
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
| Connection | From top | ||
dz47le earth leakage mini circuit breaker Temperature derating
| Temperature | -15°C | -5°C | 0°C | 10°C | 20°C | 30°C
1.00 |
40°C | 55°C |
| Temperature compensation coefficient |
1.19 |
1.15 |
1.13 |
1.06 |
1.05 |
0.96 |
0.89 |
৳ 1,650.00 ৳ 1,700.00