CHINT DZ47LE-125 Leackage Circuit Breaker 125A Multifunctional Overload Leakage ELCB
-
Rated Voltage220VTypeCircuit breaker
-
Is Smart Devicenois_customizedYes
-
Model NumberDZ47LE-125TypeMini
-
OriginMainland ChinaBrand NameChtai
-
Poles Number4PRated current In(A)125A
-
Breaking Capacity6kARated Voltage400V
-
Rated Frequency50/60HZCertificateCE
-
Electrical Life(Time)10000 TimesMechanical Life20000 Times
-
Working Temperature-5℃ to 40℃
৳ 3,550.00 ৳ 3,800.00
Related products
-
CHINT Product's List, MCB
CHINT NXB-63 3P 40A 63A 230V 380V Miniature Circuit breaker MCB NEW DZ47
0 out of 5(0)1.rated current up to10A 16A;20A;25A;32A ;40A;63A
2.breaking capacity(A):10000,6000.4500
3.rated voltage:230/400v
4.mechanical life,more 20000Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
SKU: n/a -
CHINT Product's List, ELCB
CHINT NXBLE-32 1P+N 6A 10A 16A 20A 32A 40A RCBO Earth Leakage Circuit Breakers With Leakage Protection
CHINT Product's List, ELCBCHINT NXBLE-32 1P+N 6A 10A 16A 20A 32A 40A RCBO Earth Leakage Circuit Breakers With Leakage Protection
0 out of 5(0)Circuit breaker Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In 30 mA: additional protection in the case of direct
contact In 300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
SPEC:
Standard IEC/EN 60898-1 Electrical features
Type (wave form of the earth leakage sensed) AC Thermo-magnetic release characteristic C, D Rated current In A 6, 10, 16, 20, 32, 40 Rated voltage Ue V 230/400 Rated sensitivity In A 0.03, 0.1, 0.3 Rated residual making and breaking capacity Im A
500
Rated short-circuit capacity lcn A 4,500/6,000 Break time under In s 0.1 Rated frequency Hz 50/60 Rated impulse withstand voltage (1.2/50)Uimp V
4,000
Dielectric TEST voltage at ind. Freq. for 1min kV 2 Insulation voltage Ui 500 Pollution degree 2 Mechanical features
Electrical life 2,000
Mechanical life 2,000 Contact position indicator Yes Protection degree IP20 Ambient temperature (with daily average35C)
C
-5…+40 (Special application please refer to P72 for temperature compensation correction) Storage temperature C -25…+70 Installation
Terminal connection type Cable/U-type busbar/Pin-type busbar Terminal size top/bottom for cable
mm2 25 AWG 18-3 Terminal size top/bottom for busbar
mm2 25 AWG 18-3 Tightening torque
N*m 2 In-Ibs. 18
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device Connection From top Circuit breaker Temperature derating
Temperature -15C -5C 0C 10C 20C 30C 1.00
40C 55C Temperature compensation coefficient 1.19
1.15
1.13
1.06
1.05
0.96
0.89
SKU: n/a -
CHINT Product's List, MCB
CHINT NXB-63 Circuit Breaker 1P C40A 63A Replace DZ47-63 MCB
0 out of 5(0)1.rated current up to1A-40A, 63A
2.breaking capacity(A),6000.
3.mechanical life,more 20000Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
SKU: n/a -
CHINT Product's List, MCB
CHINT NXB-63 Circuit Breaker 1P C6A 10A 16A 20A 32A Replace DZ47-63 MCB
0 out of 5(0)1.rated current up to1A-40A, 6A, 10A, 16A, 20A, 32A
2.breaking capacity(A),6000.
3.mechanical life,more 20000Temperature:-5 degree c-+40 degree c; the average value within 24h shall not exceed +35 degree ;
for the circuit breaker with themo-magnetic relaese,+40 degree is set to be the standard temperature for ratings,special utilization.
SKU: n/a













There are no reviews yet.