Fluke 1587 FC Insulation Multimeter Price in bd
Showing the single result
-
Best Selling Products, Digital Multimeters, Meters
Fluke 1587 FC Insulation Multimeter
Specification
AC Voltage MeasurementsRange:600 mV
6 V
60 V
600 V
1000 VResolution:0.1 mV
0.001 V
0.01 V
0.1 V
1 V50 to 60 Hz ±(% of Rdg + counts):±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)60 to 5000 Hz ±(% of Rdg + counts):±(2% + 3)
±(2% + 3)
±(2% + 3)
±(2% + 3)1
±(2% + 3)1Low-Pass Filter VoltageRange:600 mV
6 V
60 V
600 V
1000 VResolution:0.1 mV
0.001 V
0.01 V
0.1 V
1 V50 to 60 Hz ±(% of Rdg + counts):±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)60 to 400 Hz ±(% of Rdg + counts):±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)DC Voltage MeasurementRange:6 V DC
60 V DC
600 V DC
1000 V DCResolution:0.001 V
0.01 V
0.1 V
1 VAccuracy ±(% of Rdg + Counts):±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)Input Impedance:10 MΩ (nominal), <100 pFNominal Mode Rejection Ratio:>60 dB at 50 or 60 HzCommon Mode Rejection Ratio:>120 dB at DC, 50 or 60 Hz (1 k unbalance)DC Millivolts MeasurementRange:600 mV DCResolution:0.1 mVAccuracy ±(% of Rdg + Counts):±(0.1 + 1)DC and AC Current MeasurementRange:400 mAResolution:0.1 mAAccuracy ±(% of Rdg+Counts):±(1.5% + 2)1Burden Voltage (Typical):2 mV/mARange:60 mAResolution:0.01 mAAccuracy ±(% of Rdg+Counts):±(1.5% + 2)1Burden Voltage (Typical):2 mV/mADCRange:400 mAResolution:0.1 mAAccuracy ±(% of Rdg+Counts):±(0.2% + 2)Burden Voltage (Typical):2 mV/mARange:60 mAResolution:0.01 mAAccuracy ±(% of Rdg+Counts):±(0.2% + 2)Burden Voltage (Typical):2 mV/mAOverload:600 mA for 2 minutes maximumFuse Protection for mA Input:0.44 mA, 1000 V, IR 10 kAAC Conversion:Inputs are ac-coupled and calibrated to the RMS value of sine wave inputOhms MeasurementRange:600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩResolution:0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩAccuracy +(% of Rdg+Counts)1:±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(1.5% + 3)Overload Protection:1000 RMS or DCOpen Circuit Test Voltage:<8 V DCShort Circuit Current:<1.1 mADiode TestDiode Test Indication:Display voltage drop: 0.6 V at 1.0 mA nominal test currentAccuracy:±(2% + 3)Continuity TestContinuity Indication:Continuous audible tone for test resistance below 25 Ω and off above 100 Ω
Maximum reading: 1000 ΩOpen Circuit Voltage:<8.0 VShort Circuit Current:1.0 mA typicalOverload Protection:1000 V RMSResponse Time:>1 m secFrequency MeasurementRange:99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHzResolution:0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHzAccuracy ±(% of Rdg+Counts):±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)Frequency Counter Sensitivity600.0 mV AC:V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV
DC Trigger Levels¹ to 20 kHz2: NA6.0 V:V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V
DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V60.0 V:V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V
DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V600.0 V:V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V1000.0 V:V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 VCapacitanceRange:1000 nF
10.00 µF
100.0 µF
9999 µFResolution:1 nF
0.01 µF
0.1 µF
1 µFAccuracy ±(% of Rdg+Counts):±(1.2% + 2)
±(1.2% + 2)
±(1.2% ± 90 counts)
±(1.2% ± 90 counts)Temperature MeasurementRange:-40 to 998°F (-40 to 537°C)Resolution:0.1°F (0.1°C)Accuracy ±(% of Rdg+Counts)1:±(1% + 10 counts)
±(1% + 18 counts)Insulation SpecificationsMeasurement Range:0.01 MΩ to 2 GΩTest Voltages:50, 100, 250, 500, 1000 VTest Voltage Accuracy:20%, 0%Short-Circuit Test Current:1 mA nominalAuto Discharge:Discharge time <0.5 second for C=1 µF or lessLive Circuit Detection:Inhibit test if terminal voltage >30 V prior to initialization of testMaximum Capacitive Load:Operable with up to 1 µF loadOutput Voltage50 V (0% to +20%):Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 50.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)100 V (0% to +20%):Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 100.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)250 V (0% to +20%):Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 250 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)500 V (0% to +20%):Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 500 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 500 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)1000 V (0% to +20%):Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 600 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 0.6 to 2.0 GΩ
Resolution: 100 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)SKU: n/a